- All products
- Eenergy / Stroomtransformatoren
- HSCT-41-4V-500 Hall Effect current transformer: 500 A - Output +/- 4 V - Power supply +/-15V DC DIAM: 20mm
- Eenergy / Stroomtransformatoren
HALL EFFECT Open AC/DC current transformers HSCT21/HSCT41
Through diameter 21mm or 41mm According to the HALL effect principle
The HSCT sensors are used for all applications where direct current and variable frequencies (up to 20 kHz) need to be measured. For example, for battery monitoring systems (energy storage, UPS, emergency power supplies), speed controllers, power supplies for radio stations, power electronics, etc.
The output signals can be connected to special instruments, PLCs, etc.
By using the open-loop Hall effect measurement technique, they can be used with a core that can be opened, allowing the sensors to be easily installed without disconnecting the conductors. Removable screw terminals make installation extremely convenient.
GENERAL TECHNICAL CHARACTERISTICS
Auxiliary power supply: ± 12 or 15 V dc (+/-5%)
Operating frequency: from DC to 25 kHz
Load resistance: minimum 10 kOhm
Current consumption at supply @ 15 V dc: <16mA
Voltage output at nominal current Ip = 0: ± 25 mV
Voltage output at nominal current Ipn: ± 4 V ±1%
Measurement accuracy: 1%
Linearity: 1%
Thermal deviation of the measurement: ± 1 mV/°C
Response time 0...90%: <5 μs
Isolation between primary and secondary: 3 kV
Operating temperature: -10°C...70°C
Storage temperature: -25°C...70°C Connections: Removable terminal for cable cross-section 0.2 ÷ 2.5 mm²
Complete type list

Connection

Output signal
Vout: Nominal output ±4 V
Accuracy
ACCURACY CLASSES FOR CURRENT TRANSFORMERS
According to the applicable standards the error limits of the current and the error limits of the phase angle of each transformer must lie within the data in the table:



Dimensions
Technical properties
| Brand: | Pectech |
| Type: | HSCT-41-4V-500 |
| Diameter opening: | 41 mm |
| Primary current: | 500 A |
| Voltage output at nominal current Ip = 0: | ± 25 mV |
| Voltage output at nominal current Ipn: | ± 4 V ±1% |
| Auxiliary power: | ± 12 or 15 V dc (+/-5%) |
| Operating frequency: | from DC to 25 kHz |
| Load resistance: | minimum 10 kOhm |
| Current consumption at supply @ 15 V dc: | <16mA |
| Measurement accuracy: | 1% |
| Linearity: | 1% |
| Thermal deviation of the measurement: | ± 1 mV/°C |
| Response time 0...90%: | <5 μs |
| Isolation between primary and secondary: | 3 kV |
| Operating temperature: | -10°C...70°C |
| Storage temperature: | -25°C...70°C |
| Connections: | Removable clamp for cable cross-section 0.2 ÷ 2.5 mm² |